View All Hydrolab Products View All OTT Products View All ADCON Products View All Schlumberger Products View All Eijkelkamp Products View All Turner Products View All Hach Products
Products
DuoSens

The OTT Data loggers are especially used as station managers for Hydrometry, Meteorology and Environmental Technology. The essential functions are the collection, storage, processing, control and transmission of environmental data.

The OTT DuoSens is a compact and economical model for entering into the loggers' world. It is available in two versions:

  • OTT DuoSens Basic: Data logger without display and operating button. All settings done via configuration software.
  • OTT DuoSens Standard: Data logger with Display and operating button ("jog-shuttle") for entering observer values and for offset settings.

The two versions of the OTT DuoSens can be extended step by step by the modular system.The OTT DuoSens versions offer various sensor connecting possibilities. All major data transmission systems or services are supported. A comprehensive alarm management completes the great performance of the OTT DuoSens.

Features
  • OTT DuoSens Basic as a compact and economical model to enter into the loggers' world
  • Extendable step by step via additional modules
  • All the important data communication systems and services are supported
  • The extended voltage input range from 6...28 V allows to operate the OTT DuoSens with a simple battery pack, with 12 V or with 24 V
  • Simple and fast mounting on a backing board using 'rail & clip' click-on fastening
  • Reliable OTT quality to an unrivalled price-performance ratio
Specs
Power supply +6 … 28 V DC
Power consumption
(at 12V)
Active
Sleep
Sleep; (e.g.. com2 input active, contact closed)


approx. 15 mA
50 µA
500 µA
Clock
Type
Accuracy

real time clock RTC
+/- 1 minute/ month @ +25 °C
Communication interface
RS 232
Infrared ( IrDA )
GPRS Data transmission

1x
Angle of reflection 30°
in preparation
Memory

Number of logic channels
Reading interval
Storage interval
4 MB, non-volatile circular memory
(no loss of data at power failure)
30 + 1 info channel
5s … 24 h
5s … 24 h
Display Optional, graphics compliant DOT-matrix 122 x 32 pixels
Inputs

Number of physical input
channels

Extension channels


RS485 input (available protocols)

Voltage input
Power input
Pt 100
Pulse input
Conductivity
NTC input
Frequency input
Potentiometer


2 x pulse input fix, 1x SDI-12 fix, 1 x RS 485 fix


2 x analogue extension board (voltage, power, Pt 100)
/ 1 x RS 232 extension board""

Kalesto, Parsivel


50 mV / 5 V / 10 V (extension board)
0 … 20 mA / 4 … 20 mA (extension board)
yes (extension board)
yes
no
no
no
yes

Documents
Brochure
Manual
Related Categories
Water Quality Multiprobes
Water Level Sensors