HydroCAT

Depending on the application, the HydroCAT can collect high quality data for several months up to a year.

Excellent bio-fouling protection is provided by US EPA-approved anti-foulant devices, integral pump, and unique internal flow path, which minimizes flow between samples and provides stable measurements throughout a deployment.
Conductivity and temperature sensors are based on field proven Sea-Bird Electronics (SBE) CTD products. The aged and pressure- protected thermistor has a long history of exceptional stability and accuracy. The oxygen sensor was designed by SBE to meet the demand for a low maintenance and high accuracy sensor for use in applications such as hypoxia monitoring. All HydroCAT sensors are built with careful choices of materials and geometry combined with superior electronics and calibration methodology to optimize field performance.
Features
  • Robust: excellent anti-fouling capability - EPA approved anti-foulant device and pumped internal flow path for maximum biofouling protection

  • Accurate: each instrument is factory calibrated in a temperature-controlled bath that operates at 2-4 times the accuracy of the instrument.

  • Cost Effective: no in-field calibrations required, common deployment duration of three plus month, reducing field costs

Specs

Measured Parameters

 

Conductivity

 

Range

0 ... 70 mS/cm (0 ... 70,000 µS/cm)

Accuracy

± 0.003 mS/cm (3 µS/cm)

Typical Stability

0.003 mS/cm (3 µS/cm) per month

Resolution

0.0001 mS/cm (0.1 µS/cm)

Temperature

 

Range

-5 ... 45°C

Accuracy

± 0.002°C / ± 0.01°C (over 35°C)

Typical Stability

0.0002°C per month

Resolution

0.0001°C

Pressure

 

Range

0 ... 20 m/ 0 ... 100 m/ 0 ... 350 m

Accuracy

± 0.1% of full scale range

Typical Stability

0.05% of full scale range

Resolution

0.002% of full scale range

Optical Dissolved Oxygen

 

Range

120% of surface saturation in all natural waters

Accuracy

± 0.1 mg/L (3 µmol/kg) or ± 2% whichever is greater

Typical Stability

< 0.03 mg/L (1 µmol/kg)/100,000 samples (20°C)

Resolution

0.007 mg/L (0.2 µmol/kg)

Electrical

 

Clock Stability

5 seconds/month

Acquisition Time

2.3 ... 3.2 seconds/sample (see manual)

Power Supply

 

Internal

7.8 Amp-hour (nominal) battery pack, 257 Kjoules (derated for calculations)

Optional External Power

0.25 Amps at 9 ... 24 VDC

Power Consumption(all with pressure) *

 

Quiescent

0.0004 Watts

CTD-DO Sample Acquisition (excluding pump):

Real-time data enabled - 0.17 Watts
No real-time data - 0.155 Watts

CTD-DO Sample Waiting (not sampling, pump running, excluding pump):

Real-time data enabled - 0.056 Watts if receive line valid,
0.016 Watts if receive line not valid
No real-time data - 0.016 Watts

CTD-DO Between Samples

Real-time data enabled - 0.056 Watts if receive line valid
0.0004 Watts if receive line not valid
No real-time data - 0.0004 Watts

Pump

0.12 Watts

Communications

0.065 Watts

* Power consumption values are for standard RS-232 interface; for optional interfaces, see corresponding manual.

 

General

 

Housing Material

Plastic

Depth Rating

350 m (1148 ft)

Weight

3.4 kg (7.5 lbs) in air, 1.5 kg (3.3 lbs) in water


Documents
Brochure
Manual
Additional
Related Categories
Water Quality Multiprobes
Dataloggers
Aqualab Systems