View All Hydrolab Products View All OTT Products View All Eijkelkamp Products View All Hach Products View All Turner Products
Products
PLS

The PLS features a long-term stable, highly precise, capacitive ceramic pressure cell. This cell is extremely robust and insensitive against mechanical overload as well as against aggressive media. The sensor electronics measure pressure and temperature values. Compensating for temperature effects, water density and the specific gravitational force at the measuring site, the sensor delivers highly precise and repeatable actual water levels.

The OTT PLS can be supplied with various outputs for transferring the values to an attached datalogger - the analog 4 ... 20 mA output or the digital SDI-12 or RS-485 outputs. In addition to the waterlevel also the water temperature can be output via the serial interface.

Finally, the OTT PLS is supplied with a high quality and particularly tough stainless steel housing and even the cable for the probe is extraordinarily tough due to Kevlar fibers incorporated. 

Features
  • As the OTT PLS is relatively easy and rapid to install even without a stilling well, it is especially suitable for new measuring sites and for locations where float-operated units aren't applicable for example:
  • small diameter pipes or holes (from 1')
  • stations with sloping bottom, e.g. banks
  • waterways that do not contain water throughout the year (e.g. retaining basins or wadis)
Specs
Pressure measurement range 0 ... 4 m, 0 ... 10 m, 0 ... 20 m, 0 ... 40 m water column
Pressure sensor (capacitive pressure sensor) ceramic, temperature compensated, overload safe for up to 5 times the measuring range without permanent mechanical damage
Resolution (SDI-12)
0.001 m; 0.1 cm; 0.01 ft; 0.1 mbar; 0.001 psi
Accuracy
 SDI-12 ≤ ±0.5% FS (linearity and hysteresis)
 4 … 20 mA ≤ ±0.01% FS (linearity and hysteresis)
  10 ppm/°C at 20 °C
Long-term stability ≤ ±0.1 % /year FS (linearity and hysteresis)
Zero point drift
0.1 % FS
Temperature compensated working range  – 5 °C ... +45 °C (ice-free)
Temperature measurement range –25 °C ... +70 °C (ice-free)
Temperature sensor NTC
Resolution 0.1 °C / 0.1 °F
Accuracy ±0.5 °C / ±0.9 °F
Available interfaces (use as required) 4 ... 20 mA, SDI-12, RS485 (via SDI-12 protocol)
Supply voltage +9.6 ... +28 V DC, typically 12/24 V DC
Power consumption (SDI-12)  .
sleep < 600 µA
active < 3,6 mA
Dimensions and Weight  
Dimensions
L x Ø
195 mm x 22 mm
Weight approx. 0.3 kg
Environmental conditions  
Operating temperature – 25 ... +70 °C
Storage temperature – 40 ... +85 °C
Materials .
Housing POM, stainless steel 1.4539 (904L) resistant to sea water
Seals Viton
Cable jacket PUR
Protection type IP 68

Documents
Brochure
Manual
Related Categories
Datalogger
Integrated Systems
Water Level Sensors