| General Data |
|
| Types of precipitation |
liquid, solid and mixed |
| Collection area |
200 cm² and 400 cm² |
| Collection volume |
1500 mm and 750 mm |
| Sensor element |
sealed load cell |
| Interfaces |
|
| USB |
configuration/service mode and firmware update |
| Serial Interfaces |
SDI-12 or RS-485 |
| Digital outputs |
impulse 0.1 mm (configurable) and status (0…120 impulsee/min; configurable 5 or 2Hz ) |
| Measurement output |
intensity RT; amount RT/NRT; amount total NRT; bucket content RT and NRT; temperature of load cell |
| Electrical and mechanical data |
|
| Power supply |
9.6 to 28 VDC; Low Power: 5.5 to 28 VDC
|
| Power consumption |
typ. 12 mA at 12 V; Low Power: typ. 4.5 mA at 12 V
|
| Ring heating, optional |
Pluvio2 200: 24 VDC / max. 50 Watt
Pluvio2 400: 24 VDC / max. 100 Watt
|
| Dimensions (Ø x h) |
|
OTT Pluvio² 200/400
|
450 mm x 740 mm / 450 mm x 660 mm |
| Pedestal diameter |
(Ø) 110-120 mm ( 4 “) |
| Weight |
(empty bucket) 15 kg |
| Material |
aluminium/polyethylene/ASA, UV resistant |
| Environmental conditions |
|
| Temp, in operation |
-40 … +60 °C |
| Temp, storage |
-50 … +70 °C |
| Relative humidity |
0 … 100% (non-condensing) |
| Protection |
|
| Housing |
IP 54, resistant to salt fog |
| Load Cell / Electronic |
IP 67 / IP 64 |
| EMC |
EN 61000-4-2/4/5/6, Level 5 (4 kV) EM/EMI EN 61000-4-3, CE conform |
| Measurement ranges |
|
| Precipitation |
0…50 mm/min or 0 … 3000,00 mm/h |
| Cumulative precipitation threshold |
0.05 mm/h |
| Intensity threshold |
0.1 mm/h or 6 mm/h |
| Resolution |
|
| Impulse output |
0.1 mm |
| SDI-12 and RS-485 |
0.01 mm/min, 0.01 mm/min or mm/h |
Accuracy
(at -25°C …+45°C) |
|
| Amount |
± 0.1 mm or ±1% of measured value |
| Intensity threshold |
± 0.1 mm/min or ± 6 mm/h |
| Times |
|
| Intensity output Interval |
1 minute |
| Output delay |
RT 18 seconds NRT 5 minutes |
| Query interval |
6 seconds .... 60 minutes |