WS Series

All-in-One measuring system for the measurement of wind speed, wind direction, temperature, relative humidity, barometric pressure, global radiation and precipitation

Depending on the particular model, the instruments in the WS series provide a low-power ultrasonic wind sensor incorporating an electronic compass for automatic adjustment for magnetic North, a NTC air temperature sensor, a capacitive sensor for air humidity, a sensor for barometric pressure, one for global radiation (CMP3) and a tipping bucket rain gauge for liquid precipitation. SDI-12 Output.
Thanks to a configurable low-power mode, the units are ideally suited for all solar-powered hydro-meteorological applications.

Features
  • WS200, wind speed, wind direction, electronic compass.

  • WS300, temperature, air humidity, barometric pressure

  • WS301, temperature, air humidity, barometric pressure, global radiation

  • WS500, wind speed, wind direction, electronic compass, temperature, air humidity, barometric pressure

  • WS501, wind speed, wind direction, electronic compass, temperature, air humidity, barometric pressure, global radiation

  • WS601, wind speed, wind direction, electronic compass, temperature, air humidity, air pressure, precipitation (rain)

Specs

Wind speed

 

Measuring method

4 ultrasonic sensors with 10 Hz

Measuring range

0 … 60 m/s (WS601: 0 … 30 m/s)

Resolution

0.1 m/s

Accuracy

±0.3 m/s or ±3 % (0...35 m/s)

 

±5 % (35-60 m/s) RMS

Operating Threshold

0.3 m/s

 

 

Wind direction

 

Measuring method

4 ultrasonic sensors with 10 Hz

Measuring range

0 … 359.9°

Resolution

0.1°

Accuracy

±3°(> 1 m/s) RMS

Operating Threshold

0.3 m/s

 

 

Compass

 

Measuring method

integrated electronic

Measuring range

0… 359°

Resolution

Accuracy

±10°

Measuring rate

5 minutes

 

 

Air temperature

 

Measuring method

NTC

Measuring range

-50 … +60 °C

Resolution

0.1 °C (-20… +50 °C), otherwise 0.2 °C

Accuracy

0.2 °C (-20… +50 °C), otherwise ±0.5 °C

 

 

Dew point temperature

 

Measuring method

passive, derived from air temperature and humidity

Measuring range

-50...+60 °C

Resolution

0.1 °C

Accuracy

±0.7 °C

 

 

Air humidity

 

Measuring method

capacitive

Measuring range

0...100 % rH

Resolution

0.1 % rH

Accuracy

±2 % rH

 

 

Barometric pressure

 

Measuring method

MEMS-sensor, capacitive

Measuring range

300… 1200 hPa

Resolution

0.1 hPa

Accuracy

±0.5 hPa (0 … +40 °C)

 


Documents
Brochure
Related Categories
Precipitation Sensors
Telemetry
Soil Moisture